Actuator Fully Welded Ball Valve

  • Description
Product Detail

    03.jpg

    Product Description:

    This series of products are reliable sealing performance, maintenance-free for 20 years, switch torque light,can be installed in heat transfer stations, district heating pipe network, branch pipes, heat exchanger unit, heat transfer equipment or ancillary equipment connected to other.use for cut off . The main use of the urban heat, city gas, city water supply and drainage lines. 

    Standard type:

    zz66.png

    Full bore type:


    zz92.png

    fully-welded-ball-valve-part-list.jpg

    No.

    Part name

    Material

    1

    Body

    Carbon steel St37.8

    2

    Neck

    PTFE+SPCB

    3

    Ball

    304 stainless steel 

    4

    Stem

    2Cr13

    5

    Seat

    25%C+PTFE

    6

    Metal washer

    60Si2Mn

    7

    Spring

    60Si2Mn

    8

    "O" Ring

    FPM

    9

    End piece

    Carbon steel St37.8

    10

    Handle

    Carbon steel +HCr

    11

    "O" Ring

    FPM

    12

    Gland

    304 stainless steel 

    IMG_5322.jpg

    Five Advantages:

    1. integral seamless steel tube pressed full-auto welded without leaking outward.

    2. PTFE+25% carbon fiber and disc spring feely compensating structure zero leakage.

    3. can be directly buried without need of a high ground well,saving the engineering cost.

    4. both valve and pipeling are made of the same material, without the condition of uneven sterss.

    5. in multiple connection combination, for use with special working conditions.

    Full bore type:


    zz87.jpg

    zz88.png

    zz89.jpg

    zz90.png

    We pay much attention in Test process:

    (1) Shell Hydrostatic Test

    ANSI B 16.34 Section   7.1

    Valve Size NPS

    Test pressure

    Test Time. Sce

    Below DN50

    1:5 times the 100°F

    15 Sce

    DN65~DN200

    Rating of  ANSI  Class

    60 Sce

    Up DN250

    Max. Operating Pressure

    180 Sce


    Test pressure should   be above 1.5 times  than the valve's Max work pressure (100F)


    (2) Seal Hydrostatic Test

    The pressure should be more 1.1 times than working pressure by seal hydrastatic test

    zz78.jpg

    ANSI B 16.34   Section 7.2

    Valve Size NPS

    Test pressure

    Test Time. Sce

    below DN50

    1:1 times the 100°F

    15 Sce

    DN65~DN200

    Rating of  ANSI Class

    30 Sce

    above DN250

    Max. Operating Pressure

    60 Sce


    Test pressure should be more 1.5 times  than the valve's Max work pressure (100F)

    180Sce


    (3) Seal Air Test

    Seal air leakage test is based on 80PSIG(6kgf/cm2) inert-gas or the air reach the test pressure, then close the valve. after that check the valve whether it is leakage or not.

    FAQ 

    1.What is the MOQ?
    According to company regulations 10 sets, 5 sets is also acceptable for intentional customer.

    2.What about your payment terms?
    30% payment in advance, 70% balance pay T/T before loading.

    3.What is your delivery date?
    10-30 days after received the advance payment.

    4.Which models sell best in your factory?
    Q61C-25; Q361FC-16; Q661FC-25; Q961C-25(DN15-DN1400)

    5.What kind of certification you have?
    CE; ISO9001; EAC; API; TS...


    6.How many people in your factory? How many designer and how many QC people?
    More than 200 employees, 8 engineers, 55 QC people, 20 years experience.